News Docu Finder - Downloads Contact Company English / Worldwide + 49 7720 3903-0
PRODUCTS

Welcome to the world of measurement, transmission and evaluation.

Discover the variety of the Kübler products and solutions. Its wide portfolio ranges from standard products up to special solutions for most various sectors. We will be pleased to address also individual challenges. Modifications and special solutions will be implemented in a quick and straightforward way.

We will be happy to advise you. +49 7720 3903-952 | support@kuebler.com

SERVICE

Welcome to the Service area of the Kübler Group.

We ensure confidence and planning security all over the world. The high quality requirements we set for our products and for ourselves also reflect in our service offer. This offer ranges from competent and personal product advice, through the joint definition of the solution in case of specific challenges, to on-site commissioning. Besides high-class products, also secure long-term high service quality.

We will be happy to support you. +49 7720 3903-849 I support.int@kuebler.com

CAREER

Impulses for your career. Welcome to TOP JOB Employer.

Your personal and professional competencies are the focus of our attention. Find the right job for your future now and become a part of our success story.

We're there for you. +49 7720 3903-222 I info@kuebler.com

PRODUCTS
BACK PRODUCTS NEW PRODUCTS MEASUREMENT TRANSMISSION EVALUATION
INDUSTRIES SERVICE CAREER

Radar sensors for level measurement

Reliable measurement results of fill levels with high accuracy, even with highly fluctuating surfaces - Kübler radar fill level sensors measure precisely and error-free even with wave motion, bubble formation or other abrupt fill level fluctuations. The basis for this is a unique combination of high measuring rate and smart filter algorithms.

Radar sensors for level measurement

Reliable measurement results of fill levels with high accuracy, even with highly fluctuating surfaces - Kübler radar fill level sensors measure precisely and error-free even with wave motion, bubble formation or other abrupt fill level fluctuations. The basis for this is a unique combination of high measuring rate and smart filter algorithms.

Advantages of Kübler radar sensors


PRODUCTIVE

PRODUCTIVE

Precise level measurement even in harsh industrial environments.

RELIABLE

RELIABLE

Reliable and fast level measurement even in the presence of dust, steam, smoke, vibrations or extreme temperatures

ECONOMIC

ECONOMIC

Minimal maintenance:
no moving parts - contactless measurement - hardly any cleaning required

Level Sensor Performance
Radar
Ultrasonic
Capacitive
Radiometric
Measurement in dirt, dust, smoke, water vapor, water droplets
Robustness against extreme temperatures & pressure variations
Measurement accuracy
Measurement range
Calibration & maintenance effort
Measure tank level from outside
Acquisition cost
Radiation protection
Level Sensor Performance
Measurement in dirt, dust, smoke, water vapor, water droplets
Radar
Ultrasonic
Capacitive
Radiometric
Level Sensor Performance
Robustness against extreme temperatures & pressure variations
Radar
Ultrasonic
Capacitive
Radiometric
Level Sensor Performance
Measurement accuracy
Radar
Ultrasonic
Capacitive
Radiometric
Level Sensor Performance
Measurement range
Radar
Ultrasonic
Capacitive
Radiometric
Level Sensor Performance
Calibration & maintenance effort
Radar
Ultrasonic
Capacitive
Radiometric
Level Sensor Performance
Measure tank level from outside
Radar
Ultrasonic
Capacitive
Radiometric
Level Sensor Performance
Acquisition cost
Radar
Ultrasonic
Capacitive
Radiometric
Level Sensor Performance
Radiation protection
Radar
Ultrasonic
Capacitive
Radiometric

Radar sensors for demanding measurement tasks with liquid metal


Because certain materials are permeable to radar waves, this 
opens up installation options that are not possible with other measurement systems. 

  1. Direct measurement of molten metal.
  2. Measurement from a heat-shielded housing with a heat-resistant cover plate that is transparent to radar waves.
  3. Measurement from a heat-shielded housing through openings into a closed vessel (melting furnace).

Precise detection of the surface of liquid metal up to 1600 °C thanks to specific filter algorithms and a high measuring rate of 500 Hz

  • Opening angle ±1.5°
  • Filters out even strong surface fluctuations
  • Detects all metals and alloys
  • Insensitive to vapors, dust, smoke and heat
  • PROFINET interface with additional 4 ... 20 mA interface
    and three digital switching outputs PNP/NPN

Maximum signal strength

Mounting plate for fine angle adjustment

For an optimum measurement result, the exact alignment of the
of the sensor to the object to be measured is crucial. The maximum
signal strength of the reflected radar wave is determined by the
radar sensor is aligned at right angles to the surface of the target.
surface of the measurement object. Especially with a narrow aperture angle
the tolerances for a deviation from the perpendicular are
relatively small in order to receive a signal at all.

For fine angle adjustment of the RAD7xx radar sensor, a special
special mounting plate. Using 2 adjustment screws, the plate can be
plate can be adjusted up to ±2 mm horizontally and ±1.5 mm vertically.
Threaded holes allow the RAD7xx to be mounted both directly and
directly or with the heat protection housing to the mounting plate.
fastened

Angle reflector for optimizing the signal strength in the application

Uneven surfaces or problematic focusing on a target object at a greater
target object at a greater distance can greatly influence the signal strength of the
radar signal to be received. To increase
signal strength for greater measurement accuracy, angled reflectors can
Angle reflectors can help here.

  • Increasing the signal strength received from a target.
  • Increasing the possible angle between sensor and target.







Angle reflectors "bundle" the radar signals over a larger area.
area. The geometry is designed in such a way that reflections at each
(b+c) travel the same distance to and from the sensor as the direct reflection
the direct reflection (a) at a 90° angle.

Maximum heat protection

Heat protection housing with connection for air cooling

The heat protection housing for the RAD7xx radar sensors has an
has an active cooling system. It enables operation of the
sensors even at extreme ambient temperatures of up to
1600 °C.

RAD78L applications in the steel industry


Monitoring the molten metal level in open and closed furnaces

Monitoring the molten metal level in open and closed furnaces

  • Recommended variant RAD78L :
    Liearity ±2 mm / Measuring range 0.3 ... 30 m
  • In the corresponding protective housing measurements through small openings
    in the oven lid (50 mm) possible
Liquid metal level, e.g. in casting ladles or torpedo cars - Measurements from distances of up to 20 m

Liquid metal level, e.g. in casting ladles or torpedo cars - Measurements from distances of up to 20 m

  • Recommended variant RAD78L :
    Liearity ±2 mm / Measuring range 0.3 ... 30 m
  • Additional heat protection by housing for 90° reflection of the radar signal
    radar signal
Plate and ingot casting - control of the filling level of the casting pit with maximum linearity up to ±0.3 mm

Plate and ingot casting - control of the filling level of the casting pit with maximum linearity up to ±0.3 mm

  • Recommended variant RAD78L :
    Liearity ±0.3 mm / Measuring range 0.1 ... 6 m
  • High accuracy even from a distance of 6 meters
Drainage channels and ducts - Quick and precise determination of the drainage level even with strong surface movement

Drainage channels and ducts - Quick and precise determination of the drainage level even with strong surface movement

  • Recommended variant RAD78L :
    Liearity ±0.3 mm / Measuring range 0.1 ... 6 m
  • Measurement even in narrow channels due to narrow opening angle ±1.5°

Radar sensors for simple measurement tasks in a compact design


Because certain materials are permeable to radar waves, this 
opens up installation options that are not possible with other 
measurement systems. 

  1. Direct measurement on liquid surfaces.
  2. Sensor integrated into a sealed metal container.
  3. Measurement from the outside through the wall of a 
    plastic container.

Wide field of view of ±8° for simple
measurement tasks

  • Linearity up to ±10 mm / Repeatability up to ±5 mm
  • Measuring range: max. 0.15 … 30 m
  • Measurement frequency: 30 Hz

Wide field of view of ±8° for a larger
detection range

  • Linearity up to ±10 mm / Repeatability up to ±2 mm
  • Measuring range: max. 0.15 … 30 m
  • Measurement frequency: 100 Hz

Narrow angle of view of ±3° for focused
measurement with a small measurement spot

  • Linearity up to ±5 mm / Repeatability up to ±1 mm
  • Measuring range: max. 0.15 … 40 m
  • Measurement frequency: 100 Hz

Maximum Signal Strength

Mounting Bracket for Optimal Alignment of the Sensor with the Application

Precise alignment of the sensor with the object being measured is crucial for optimal measurement results. The maximum signal strength of the reflected radar wave is achieved when the radar sensor is aligned at a right angle to the surface of the object being measured.  Especially with a narrow beam angle, the tolerances for deviation from the vertical are relatively small in order to receive a signal at all.

Appropriate mounting brackets are available for the
RAD5xx series to ensure fast and accurate alignment—either for rotations around one or two axes perpendicular to the measurement direction.

Angular Reflector for Optimizing Signal Strength in the Application

Uneven surfaces or difficulties focusing on a target object at a greater distance can significantly affect the signal strength of the radar signal to be received. Angular reflectors can help increase signal strength to improve measurement accuracy.

  • Increase in the signal strength received from a target.
  • Increasing the possible angle between the sensor
    and the target.

Angular reflectors “focus” the radar signals over a wider area. Their geometry is designed so that reflections from any point (b+c) travel the same distance to and from the sensor as the direct reflection (a) at a 90° angle.

Maximum Transparency

ConfigBox for easy visualization of the echo curve as well as
adjustment of parameters and filter functions.

For transmitting sensor data to a PC or laptop. After connecting the sensor to the PC via the ConfigBox, the configuration software is opened in the browser. 

The software can be used to configure the sensor to meet specific
application requirements or to check its status during operation. In addition to visualizing the echo curve, the following settings can be configured: 

  • Configuration of the analog interface
  • Setting the switching points for the switching outputs
  • Setting the measurement range
  • Setting the signal threshold
  • Selection of the desired signal when multiple peaks are present
  • and much more
Level measurement in containers with liquids
Level measurement in containers with liquids
Water level measurements in open waters
Water level measurements in open waters